Volumetric Glassware Facts Worth Noting
When it comes to chemistry laboratories, a variety of glassware products is indispensable. These glassware products offer a range of purposes. In the field of quantitative chemistry, for example, the accurate measurement of liquids is a must. When it comes to measuring volumes in chemistry labs, the error percentage should only be 0.1% or one part per thousand. For this purpose, you need proper volumetric glassware products. For this glassware product, it is capable of delivering or containing a certain volume in a few hundredths of a milliliter. This goes to say that you can use these products to measure quantities between the 10 mL and four-figure range.
You can expect volumetric glassware providing this kind of precision and accuracy to be expensive for laboratory use. For the best results, it is never enough to get the most precise and high-quality volumetric glassware in the market but also, you have to hire skilled and careful technicians for such a job. If you talk about volumetric glassware used in chemistry labs, there are four main types. These include the pipet, the buret, the volumetric flask, and the graduated cylinder. Each kind of volumetric glassware offers a good range of functions. While they function differently, you can expect them to have some common functions. If you talk about volumetric glassware products, they are all similar in terms of their level of cleanliness as well as accuracy in reading volumes. You can view here for more info.
Cleanliness is a requirement in volumetric glassware to get good results. With glass that is chemically clean, you can get proper support for a uniform water film. There will not be any hanging droplets that you can see. To achieve clean volumetric glassware products, make sure to rinse them with deionized water after using them. It will be best to wash the volumetric glassware before using it if you are not sure if they are clean. For some kinds of volumetric glassware, you need to condition the apparatus by rinsing it with a few drops of the solution that you will be measuring before starting the actual work. Doing this process prevents any presence of water droplets from diluting the solution that you need and changing its concentration.
With volumetric glassware products, you will see that they are all calibrated properly. The use of markings helps with the calibration so that you can get the volume of the liquid using different accuracy degrees. The meniscus of the liquid is what you use to get the accurate volume measurement of any liquid in the glassware. The meniscus is the bottom part of the curved liquid surface. You need to locate it at the line to get the volume. If you want to see the meniscus easier, you can put a white card or paper behind the apparatus. You should not determine the meniscus above or below eye level because you will be getting inaccurate readings. Use the eye level to get volume readings.